Apogee MQ-210

Apogee MQ-210 Underwater Quantum Light PAR Meter User Manual

Model: MQ-210

1. Ynlieding

The Apogee MQ-210 Quantum Light PAR Meter is designed for precise measurement of Photosynthetic Active Radiation (PAR) in underwater environments. This device features a waterproof quantum sensor connected to a handheld meter. The MQ-210 is specifically engineered to apply an immersion effect correction factor directly through its firmware, ensuring accurate readings in aquatic settings. It is suitable for various light sources, though specific post-measurement correction factors may be required for LED light sources to achieve optimal accuracy.

Important Note: While the sensor and its cable are fully waterproof, the handheld meter unit is NOT waterproof and must be kept dry.

2. Safety Information

  • Always ensure the handheld meter remains dry. Exposure to water will damage the unit and void the warranty.
  • Do not attempt to open or modify the handheld meter or the sensor. This can lead to damage and inaccurate readings.
  • Handle the sensor cable with care to prevent kinks or damage, which could compromise its waterproof integrity.
  • Keep the device away from extreme temperatures and direct sunlight when not in use.
  • Use only specified batteries (if applicable, refer to product packaging or Apogee documentation).

3. Package Ynhâld

Kontrolearje by it útpakken oft alle folgjende ûnderdielen oanwêzich binne:

  • Apogee MQ-210 Handheld Meter
  • Waterproof Quantum Sensor (attached via cable)
  • User Manual (dit dokumint)

4. Produkt Overview

The MQ-210 system comprises two main parts: the handheld display unit and the waterproof quantum sensor.

Apogee MQ-210 Underwater Quantum Light PAR Meter with handheld unit and sensor

Ofbylding 1: Apogee MQ-210 Underwater Quantum Light PAR Meter. This image displays the complete MQ-210 unit, featuring the handheld meter with its digital display and control buttons, connected by a cable to the compact, black waterproof quantum sensor. The sensor is designed for submersion, while the handheld unit is for dry use.

4.1 Handheld Meter

The handheld meter features a digital display for showing PAR readings in µmol m⁻² s⁻¹. It includes control buttons for power, sampling, and mode selection. The meter processes the raw sensor data and applies the immersion effect correction factor.

4.2 Waterproof Quantum Sensor

Close-up of Apogee waterproof quantum sensor

Ofbylding 2: Close-up view of the Apogee waterproof quantum sensor. This image highlights the robust, anodized aluminum body and the acrylic diffuser of the sensor head. The sensor contains a blue-enhanced silicon photodiode and custom optical filters, designed for accurate underwater PAR measurements.

The sensor incorporates a blue-enhanced silicon photodiode and custom optical filters housed within a rugged, anodized aluminum body with an acrylic diffuser. It is designed for full submersion in water, making it ideal for applications such as saltwater aquariums.

5. Opsette

  1. It apparaat útpakke: Carefully remove the handheld meter and sensor from its packaging.
  2. Kontrolearje op skea: Check the handheld meter, sensor, and cable for any visible signs of damage. If damage is found, do not proceed with setup and contact support.
  3. Batterijynstallaasje (as fan tapassing): If the meter requires user-installed batteries (not specified, but common for handheld devices), open the battery compartment (usually on the back) and insert the correct type and number of batteries, observing polarity.
  4. Sensor ferbining: The quantum sensor is permanently attached to the handheld meter via a waterproof cable. Ensure the cable connection point to the sensor is secure and undamaged.
  5. Initial Power On: Press the power button on the handheld meter to turn it on. The display should illuminate and show a reading.

6. Bedriuwsinstruksjes

6.1 Yn-/útskeakelje

  • Om de meter oan te setten, druk op de Krêft button (usually marked with a circle and vertical line symbol).
  • Hâld de knop yn om út te skeakeljen Krêft knop oant it display útgiet.

6.2 Meitsje mjittingen

  1. Posysje fan de sensor: Carefully submerge the waterproof quantum sensor into the water at the desired depth and location for measurement. Ensure the sensor's acrylic diffuser is clean and unobstructed.
  2. Observe Readings: The handheld meter's display will show the real-time PAR reading in µmol m⁻² s⁻¹. The MQ-210 automatically applies the immersion effect correction factor in its firmware for underwater measurements.
  3. Sampling (if applicable): If the meter has a "sample" button, pressing it may log the current reading or provide a stable reading. Refer to the on-screen indicators for specific sampling funksjes.
  4. Modusseleksje (as fan tapassing): Use the "mode" button to cycle through different display modes or settings if available.

6.3 LED Light Source Considerations

While the MQ-210 is excellent for most light sources, when measuring PAR from LED light sources, post-measurement correction factors may need to be applied for the most accurate results. Consult Apogee Instruments' official documentation or website for specific correction factors pertaining to various LED types.

7. Underhâld

7.1 Cleaning

  • Sensor: After each use in water, rinse the sensor with fresh water to remove any salt, debris, or biological film. Gently wipe the acrylic diffuser with a soft, non-abrasive cloth. Avoid using harsh chemicals or abrasive materials that could scratch the diffuser.
  • Handheld Meter: Clean the handheld meter with a dry, soft cloth. Do not use liquid cleaners or immerse the meter in water.

7.2 Opslach

  • Store the MQ-210 in a cool, dry place away from direct sunlight and extreme temperatures.
  • If storing for extended periods, remove batteries from the handheld meter to prevent leakage (if applicable).
  • Keep the sensor and cable free from kinks or sharp bends during storage.

8. Probleemoplossing

ProbleemMooglike oarsaakOplossing
De meter giet net oan.Deade of ferkeard ynstalleare batterijen.Ferfange batterijen mei nije, soargje foar juste polariteit.
Unkrekte of ûnregelmjittige lêzingen.
  • Dirty sensor diffuser.
  • Damaged sensor or cable.
  • Incorrect application of LED correction factor (for LED sources).
  • Clean the sensor diffuser gently.
  • Inspect sensor and cable for damage. If damaged, contact support.
  • Refer to Apogee documentation for LED correction factors.
Display shows "Error" or unusual characters.Ynterne storing of sensorprobleem.Try powering off and on again. If the error persists, contact Apogee Instruments support.
Knoppen reagearje net.Internal button malfunction or software issue.Power cycle the device. If buttons remain unresponsive, contact Apogee Instruments support.

9. Spesifikaasjes

EigenskipDetail
ModelMQ-210
Type mjittingUnderwater Photosynthetic Active Radiation (PAR)
Soart sensorBlue-enhanced silicon photodiode with custom optical filters
Sensor Body MateriaalRugged, anodized aluminum with acrylic diffuser
Immersion Effect CorrectionAutomatically applied via firmware
Handheld Meter Water ResistanceNet wetterdicht
Sensor wetterresistinsjeFolslein wetterdicht
FabrikantApogee Instruments

10. Garânsje en stipe

For detailed warranty information, technical support, or service inquiries, please contact Apogee Instruments directly. Refer to their official webside foar de meast aktuele kontaktgegevens en garânsjebelied.

It is recommended to register your product with Apogee Instruments to ensure you receive updates and support.

© 2023 Apogee Instruments. All rights reserved.

Relatearre dokuminten - MQ-210

Preview Apogee MQ-510 Underwater Quantum Meter Owner's Manual
Comprehensive owner's manual for the Apogee MQ-510 Underwater Quantum Meter, covering specifications, operation, maintenance, troubleshooting, and warranty information. Learn about PAR, PPFD, immersion effect, and calibration.
Preview Apogee Instruments MQ-510 Underwater Quantum Meter brûkershantlieding
Brûkershânlieding foar de Apogee Instruments MQ-510 Underwater Quantum Meter, mei details oer de spesifikaasjes, operaasje, ûnderhâld, probleemoplossing en garânsje-ynformaasje.
Preview Apogee Instruments MQ-501 Quantum Meter Owner's Manual
Owner's manual for the Apogee Instruments MQ-501 Quantum Meter, detailing specifications, operation, maintenance, troubleshooting, and warranty information for measuring photosynthetic photon flux density (PPFD).
Preview Advanced Quantum PAR Meter User Manual and Specifications
Comprehensive user manual for the CD50 Advanced Quantum PAR Meter, covering setup, operation, troubleshooting, and technical specifications for measuring Photosynthetically Active Radiation.
Preview DANOPLUS Wetterdichte PAR-meter brûkershantlieding
Brûkershânlieding foar de DANOPLUS wetterdichte PAR-meter, mei details oer de funksjes, spesifikaasjes, gebrûksynstruksjes en probleemoplossing foar it mjitten fan fotosyntetysk aktive strieling (PAR)-flux yn túnbou- en plantfysiologystúdzjes.
Preview Apogee SQ-521 Quantum Sensor ynstallaasje- en brûkershantlieding
Útwreide hantlieding foar it ynstallearjen, ferbinen en ynterpretearjen fan gegevens fan Apogee SQ-521 Quantum Sensors mei METER ZENTRA Series Data Loggers. Omfettet ynformaasje oer probleemoplossing en stipe.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.