BTMETER BT-1800

BTMETER BT-1800 Hege Temperatuer Ynfraread Termometer Brûkershânlieding

Model: BT-1800 | Brand: BTMETER

Ynlieding

This manual provides detailed instructions for the safe and effective operation of your BTMETER BT-1800 High Temperature Infrared Thermometer. Please read this manual thoroughly before use and retain it for future reference.

The BT-1800 is a non-contact infrared thermometer designed for measuring extremely high temperatures in industrial applications such as metal melting furnaces, forges, kilns, and ceramic firing. It features a wide temperature range, high distance-to-spot ratio, and adjustable emissivity for accurate measurements.

Safety Information

  • Laser feiligens: This device uses a Class 2 laser product (Wavelength 630-670 nm, Output <0.5mW). Do not stare directly into the laser beam. Avoid directing the laser beam at eyes or reflective surfaces.
  • Bedoeld gebrûk: This thermometer is designed for measuring the temperature of inanimate objects only. It is not accurate for measuring human or animal body temperature and should not be used for medical purposes.
  • Behanneling: Behannelje it apparaat foarsichtich. Foarkom dat it falt of oan sterke stoten bleatsteld wurdt.
  • Miljeu: Stel it apparaat net bleat oan ekstreme temperatueren, fochtigens of korrosive omjouwings.
  • Reiniging: Ferwize nei de Ûnderhâld seksje foar goede cleaning ynstruksjes.

Produkt oerview

The BTMETER BT-1800 is a handheld infrared thermometer featuring a robust design and advanced measurement capabilities. Key components are illustrated below:

BTMETER BT-1800 Infrared Thermometer with labeled parts
Figure 1: BTMETER BT-1800 Infrared Thermometer with labeled components including LCD screen, mode button, laser button, trigger, backlight/flashlight button, unit conversion buttons, and battery door.
  • LCD skerm: Displays temperature readings, mode indicators, and settings.
  • MODE knop: Used to cycle through measurement modes (MAX/AVG/MIN/DIF/LAL/HAL), select emissivity, and set high/low temperature alarms.
  • Laser Pointer Button: Toggles the laser pointer on/off.
  • Trigger: Activates measurement and laser.
  • Backlit Screen/Flashlight Button: Toggles screen backlight and the integrated flashlight.
  • °C/DN Button: Changes temperature unit to Celsius and navigates down in menus.
  • °F/UP Button: Changes temperature unit to Fahrenheit and navigates up in menus.
  • Batterij doar: Provides access for battery installation.
BTMETER BT-1800 Infrared Thermometer front view
figuer 2: Front view of the BTMETER BT-1800 Infrared Thermometer, showing the laser hole and infrared lens.

The device also features a metal screw hole for tripod mounting and a D-shape buckle for attachment to belt loops, enhancing portability and stability during use.

BTMETER BT-1800 Infrared Thermometer showing tripod mount and D-shape buckle
Figure 3: The BT-1800 with its tripod mounting screw hole and D-shape buckle for secure carrying. Note: Tripod is not included.

Opsette

Batterij Ynstallaasje

The BT-1800 requires a 9V battery for operation. Follow these steps to install or replace the battery:

  1. Sykje it batterijfak op 'e hânfet fan' e termometer.
  2. Iepenje de batterij doar.
  3. Connect the 9V battery to the battery connector, ensuring correct polarity.
  4. Place the battery into the compartment and close the battery door securely.
Video 1: Demonstrates the process of removing and inserting the 9V battery into the BTMETER BT-1800 Infrared Thermometer. This video also shows how to attach the carabiner to the device's base.

Attaching the Carabiner

For convenient carrying, you can attach the provided carabiner to the base of the thermometer:

  1. Locate the small screw at the bottom of the handle.
  2. Use a small screwdriver to remove this screw.
  3. Insert the carabiner's loop into the hole and secure it by re-inserting and tightening the screw.

Operating Instructions

Fideo 2: Jout in algemien oersjochview of the BTMETER BT-1800 Industrial Pyrometer, demonstrating its features and basic operation, including temperature measurement and mode changes.

Basic Temperature Measurement

  1. Rjochtsje de termometer op it doelobjekt.
  2. Druk en hâld de Trigger to begin measurement. The laser pointer will activate to indicate the measurement area.
  3. The temperature reading will be displayed on the LCD screen. Release the trigger to hold the reading.
BTMETER BT-1800 Infrared Thermometer measuring temperature of molten metal
Figure 4: The BT-1800 in use, demonstrating non-contact temperature measurement of a high-temperature object.
Examples of temperature readings on the BTMETER BT-1800 for a hot object and a cold object
Figuer 5: Examples of temperature readings displayed on the BT-1800, showing measurements for both high (1989°F) and low (44.9°F) temperatures.

Ienheidskonverzje (°F/°C)

Om te wikseljen tusken Celsius (°C) en Fahrenheit (°F), druk op de °C/DN or °F/UP button while the device is on.

Mode Selection and Emissivity Adjustment

Druk op de WIZE button to cycle through various functions:

  • MAX: Toant de maksimale temperatuer dy't tidens in scan is registrearre.
  • MIN: Toant de minimale temperatuer dy't tidens in scan is registrearre.
  • AVG: Toant de gemiddelde temperatuer dy't opnommen is tidens in scan.
  • DIF: Displays the difference between the maximum and minimum temperatures.
  • LAL (Low Alarm): Set a low temperature alarm. The device will flash if the measured temperature falls below this value.
  • HAL (High Alarm): Set a high temperature alarm. The device will flash if the measured temperature exceeds this value.
  • Emissivity (E): Adjust the emissivity setting (0.1 to 1.0) to match the surface being measured for improved accuracy. Consult a reference table for common material emissivities.

To adjust values (e.g., alarm thresholds or emissivity), use the °F/UP en °C/DN buttons after selecting the desired mode with the WIZE knop.

Laser Pointer and Flashlight

  • Druk op de Laser Pointer Button to turn the laser on or off. The BT-1800 features dual laser pointers for precise targeting.
  • Druk op de Backlit Screen/Flashlight Button to activate the screen backlight or the integrated flashlight for use in dark environments.
BTMETER BT-1800 Infrared Thermometer showing dual laser pointers
Figure 6: The BT-1800 features dual laser pointers to accurately define the measurement area.

Ofstân nei puntferhâlding (D:S)

The BT-1800 has a Distance to Spot (D:S) ratio of 50:1. This means that at a distance of 50 units from the target, the measurement spot diameter will be 1 unit. A higher D:S ratio allows for accurate temperature measurement from a greater distance, which is crucial for high-temperature applications.

Diagram illustrating the 50:1 Distance to Spot Ratio of the BTMETER BT-1800
Figure 7: Illustration of the 50:1 Distance to Spot Ratio, showing how the measurement spot size increases with distance.

Auto Power Off

The device features an automatic power-off function to conserve battery life. It will power off after a period of inactivity.

Ûnderhâld

  • Reiniging: Om skjin it apparaat, wipe it mei in sêft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the lens is clean for accurate readings.
  • Batterij ferfanging: Replace the 9V battery when the low power indicator appears on the display. Refer to the "Battery Installation" section for instructions.
  • Opslach: Bewarje de thermometer yn in koel, droech plak as net yn gebrûk.

Troubleshooting

ProbleemMooglike oarsaakOplossing
Unjildich temperatuerlêzingen
  • Incorrect emissivity setting for the target material.
  • Target object does not fill the measurement spot.
  • Infrared lens is dirty or obstructed.
  • Measuring highly reflective surfaces directly.
  • Adjust the emissivity setting (E) to match the surface being measured.
  • Move closer to the target or ensure the target is larger than the measurement spot.
  • Clean the infrared lens with a soft, dry cloth.
  • For reflective surfaces, apply a non-reflective matte paint or tape to the measurement area and measure its temperature after it stabilizes.
Apparaat giet net oan
  • Batterij is dea of ​​ferkeard ynstallearre.
  • Replace the 9V battery with a fresh one.
  • Ensure the battery is correctly connected to the terminals and the battery door is securely closed.
Screen Not Displaying Correctly / Blank Screen
  • Device malfunction or internal error.
  • Attempt to remove and reinsert the battery.
  • If the issue persists, contact customer support for assistance or warranty claim.

Spesifikaasjes

EigenskipDetail
MerkBTMETER
Model NammeBT-1800
Special FeatureNet-kontakt
KleurBT-1800 Blue (-58°F ~3272°F)
Ynbegrepen komponintenYndustriële termometer
Outer MateriaalPlestik
Spesifikaasje MetCE, FCC
Display TypeDigitaal
Konnektivität TechnologyYnfraread
Produkt Care YnstruksjesWiskje skjin
Power BoarneBatterij oandreaun (9V)
Temperatuerberik-58 ° F ~ 3272 ° F (-50 ° C ~ 1800 ° C)
Krektens
  • +/- 3% +3 digits for -58 to 320°F
  • +/- 2% +2 digits for 32 to 2120°F
  • +/- 3% +3 digits for 2120 to 3272°F
Response Tiid0.25 sekonden
Repeatabiliteit1% fan lêzen of 1 °C
Ofstân nei puntferhâlding (D:S)50:1
EmissiviteitFerstelber 0.1 oant 1.0
Laser TypeClass 2, Wavelength 630-670 nm, Output <0.5mW
Item Gewicht0.44 pûn sterling
Binnen / bûtengebrûkOutdoor
ReusabilityReusable

Garânsje en stipe

The BTMETER BT-1800 Infrared Thermometer comes with a 1-jierrige garânsje from the date of purchase, covering manufacturing defects. For warranty claims, technical support, or any inquiries, please contact BTMETER customer service.

Manufacturer: BTMETER

Foar ekstra boarnen en produktynformaasje kinne jo de BTMETER Store.

Ask a question about this manual