UOTEK UT-850N

UOTEK UT-850N 1-Port USB to RS-485/422 Serial Converter

User Manual

1. Ynlieding

The UOTEK UT-850N is a universal USB to RS-485/422 serial converter designed to bridge the communication gap between modern PCs and industrial equipment utilizing RS-485/422 interfaces. This device converts USB signals to balanced differential RS-485/422 signals, providing essential connectivity without requiring an external power supply. It features surge and ESD protection, ensuring reliable data transmission in various environments.

This manual provides detailed instructions for the setup, operation, and maintenance of your UT-850N converter.

UOTEK UT-850N USB to RS-485/422 Converter

Image 1.1: UOTEK UT-850N USB to RS-485/422 Serial Converter with included terminal block.

2. Features

  • Noarmen: USBV1.1, RS-485/422 EIA.
  • USB-sinjaal: VCC, DATA+, DATA-, GND, FG.
  • RS-485 Signal: T+, T-, GND.
  • RS-422 Signal: T+, T-, R+, R-, GND.
  • Wurkmodus: Asynchronous, point-to-point or point-to-multipoint, 2-wire half-duplex or 4-wire full-duplex.
  • Rjochtingskontrôle: Automatic data flow direction control technology.
  • Baudrate: 300-921.6Kbps, auto-detect serial signal.
  • Laadkapasiteit: Supports point-to-multipoint communication, connecting up to 32 sets of RS-422 or RS-485 devices.
  • Oerdracht ôfstân: Up to 5,000m (9,600bps) for RS-485/422; up to 5m for USB.
  • Port beskerming: Surge protection, ±15KV ESD protection.
  • Connectors: USB-A male, DB9 male.
  • Oerdracht media: Twisted-pair or shielded cable.
  • Kabellengte: 1.5m.
  • Bedriuwstemperatuer: -20 °C oant 75 °C.
  • Relative Feuchte: 5% oant 95%.
  • Support foar bestjoeringssysteem: Windows (Android/2000/2003/2008/2012/XP/Vista/7/8/8.1/10/CE), Mac, Linux.

3. Opsette

3.1 Driver ynstallaasje

For Windows 8, Windows 10, and newer operating systems, the UT-850N converter typically operates driver-free (plug & play). For older operating systems such as Windows 2000/2003/XP/Vista/7, or for specific Linux/Mac OS versions, driver installation may be required. Please refer to the manufacturer's website for the latest driver downloads if automatic installation does not occur.

UOTEK UT-850N Compatibility with Multiple Systems

Image 3.1: The UT-850N converter supports various operating systems, including Windows, Mac, Linux, and Android.

3.2 Hardwareferbining

  1. Connect the USB-A male connector of the UT-850N to an available USB port on your computer.
  2. Identify the RS-485/422 interface on your industrial device.
  3. Connect the DB9 male connector of the UT-850N to your RS-485/422 device. Use the included terminal block for screw-terminal connections if your device requires it.
UOTEK UT-850N with Terminal Block Connected

Image 3.2: The UT-850N converter connected to a terminal block for RS-485/422 wiring.

3.3 Wiring Diagrams and Pin Assignments

The UT-850N uses a DB9 male connector for RS-485/422. The pin assignments are crucial for correct communication. Refer to the following diagrams for standard wiring configurations.

Hardware Definition and Initial Setting for UT-850N

Image 3.3: Pin assignments for DB9 male connector and physical dimensions of the UT-850N.

USB to RS-485 and RS-422 Conversion Diagrams

Image 3.4: Wiring diagrams for USB to RS-485 (point-to-point, multipoint, half-duplex) and USB to RS-422 (point-to-point, multipoint, full-duplex) connections.

4. Bestjoeren

4.1 Working Modes

The UT-850N supports both RS-485 (2-wire half-duplex) and RS-422 (4-wire full-duplex) communication modes. It can be configured for point-to-point or point-to-multipoint communication. The device features internal zero-delay auto receiving and transmitting functions, automatically controlling data flow direction without requiring handshake signals (RTS, DTR).

4.2 Baud Rate

The converter automatically detects the serial signal baud rate, supporting a range from 300bps to 921.6Kbps.

4.3 LED Indicators

The UT-850N is equipped with LED indicators to show its status:

  • Power ljocht: Indicates that the device is powered on and connected to the USB port.
  • RXD (Receive Data) Light: Flashes when data is being received by the converter from the RS-485/422 side.
  • TXD (Transmit Data) Light: Flashes when data is being transmitted by the converter to the RS-485/422 side.
UT-850N LED Indicators for Power, RXD, and TXD

Ofbylding 4.1: Close-up view of the UT-850N showing the Power, RXD, and TXD LED indicators.

5. Underhâld

To ensure the longevity and optimal performance of your UOTEK UT-850N converter, follow these maintenance guidelines:

  • Hâld droech: Meitsje it apparaat bleatsteld oan focht of floeistoffen.
  • Foarsichtich skjinmeitsje: Use a soft, dry cloth to clean the exterior. Do not use harsh chemicals or solvents.
  • Temperatuerkontrôle: Operate and store the device within the specified temperature range (-20°C to 75°C).
  • Kabelsoarch: Avoid bending or kinking the cable excessively to prevent internal damage.
  • ESD-beskerming: While the device has built-in ESD protection, always handle it with care, especially in dry environments, to minimize static discharge risks.

6. Probleemoplossing

If you encounter issues with your UT-850N converter, consider the following:

  • Gjin stroomljocht: Ensure the USB cable is securely connected to both the converter and the computer. Try a different USB port or computer.
  • No Data Transmission (RXD/TXD not flashing):
    • Verify all RS-485/422 wiring connections are correct according to the diagrams in Section 3.3.
    • Check the baud rate settings on both your computer's serial port software and the connected industrial device. Ensure they match.
    • Confirm that the industrial device is powered on and functioning correctly.
    • For older operating systems, ensure the correct drivers are installed.
  • Intermittent Connection/Data Errors:
    • Check for electromagnetic interference (EMI) sources near the cable. Use shielded cables if necessary.
    • Ensure the transmission distance does not exceed the specified limits (5,000m for RS-485/422, 5m for USB).
    • Verify that the terminal resistors are correctly applied in RS-485/422 networks, especially for long distances or multi-point setups.
  • Apparaat net werkenber troch PC: Try connecting to a different USB port. Reinstall or update the USB serial port drivers if applicable.

7. Spesifikaasjes

EigenskipSpesifikaasje
ModelUT-850N
StandertsUSBV1.1, RS-485/422 EIA
USB SignalVCC, DATA+, DATA-, GND, FG
RS-485 SinjaalT+, T-, GND
RS-422 SinjaalT+, T-, R+, R-, GND
WurkmodusAsynchronous, point-to-point/multipoint, 2-wire half-duplex or 4-wire full-duplex
RjochtingskontrôleAutomatic data flow direction control
Baud Rate300-921.6Kbps (auto-detect)
LaadkapasiteitUp to 32 RS-422 or RS-485 devices
Transmission OfstânRS-485/422: 5,000m (at 9,600bps); USB: ≤ 5m
Port beskermingSurge, ±15KV ESD protection
ConnectorsUSB-A male, DB9 male
Oerdracht MediaTwisted-pair or shielded cable
Kabel Lengte1.5m
Operating Temperatuer-20 °C oant 75 °C
Relative Feuchte5% oant 95% (net-kondensearjend)
Stipe OSWin Android/2000/2003/2008/2012/XP/Vista/7/8/8.1/10/CE, Mac, Linux
Item Gewicht5.5 oz
Package Ofmjittings8.15 x 5.98 x 1.46 inch

8. Garânsje en stipe

For warranty information and technical support, please refer to the official UOTEK webside of nim kontakt op mei jo autorisearre dealer. Bewarje jo oankeapbewiis foar garânsjeclaims.

© 2023 UOTEK. All rights reserved.