OREiN OL3600354

OREiN 4500LM/30W Hardwired Motion Sensor LED Flood Light

Model: OL3600354 - Instruction Manual

1. Ynlieding

Thank you for choosing the OREiN 4500LM/30W Hardwired Motion Sensor LED Flood Light. This manual provides essential information for the safe installation, operation, and maintenance of your new flood light. Please read these instructions thoroughly before installation and retain them for future reference.

2. Safety Information

WARSKÔGING: Risiko op elektryske skok. Skeakelje de stroom út by de zekering of stroomûnderbrekker foardat jo ynstallearje of ûnderhâld dogge.

  • Installation must be performed by a qualified electrician or person familiar with the construction and operation of the product and the hazards involved.
  • Soargje foar it oanbod voltage is korrekt (120V AC).
  • Net ynstallearje tichtby brânbere materialen.
  • Draach feilichheidsbrillen en wanten tidens de ynstallaasje.
  • This fixture is designed for outdoor use and is IP65 waterproof rated.

3. Package Ynhâld

Kontrolearje oft alle ûnderdielen oanwêzich binne foardat jo begjinne mei de ynstallaasje:

  • Ljochtarmatuur (1)
  • Montagebeugel (1)
  • Skroeven (ferskate maten)
  • Wiremoeren (3)
  • Ynstruksje (1)

4. Produkt Overview

The OREiN Flood Light features three adjustable LED heads and a motion sensor for comprehensive outdoor illumination and security.

OREiN 4500LM/30W Hardwired Motion Sensor LED Flood Light

figuer 1: Front view of the OREiN 4500LM/30W Hardwired Motion Sensor LED Flood Light, showing the three adjustable light heads and the motion sensor below.

Flexible Adjustment Angle of OREiN Flood Light

Figure 2: Diagram illustrating the flexible adjustment angles of the three light heads (340°) and the motion sensor (270° horizontally, 120° vertically).

5. Ynstallaasje

This flood light is designed for hardwired installation on a standard junction box (2.75” / 3.5”). It supports both wall and eave mounting.

Ynstallaasje stappen:

  1. Power útskeakelje: Disconnect power at the circuit breaker before starting.
  2. Feilige montagebeugel: Attach the metal mounting bracket to your existing junction box using the provided screws.
  3. Ferbine Wires: Connect the household wiring to the fixture wires using the provided wire nuts. Typically, black to black (live), white to white (neutral). This light belongs to secondary luminaires, so no extra ground wire connection is needed.
  4. Befeiligje de ljochtarmatuur: Align the light fixture with the mounting bracket and secure it with the appropriate screws.
  5. Wetterdichte stekker ynfoegje: Ensure the waterproof plug is properly inserted to prevent moisture ingress.
  6. Ljochtkoppen en sensor oanpasse: Position the three light heads and the motion sensor to cover the desired areas.
  7. Kracht werstelle: Skeakelje de macht wer op by de circuit breaker.
Installation Diagram for OREiN Flood Light

Figure 3: Step-by-step diagram for hardwired installation, showing mounting bracket, wire connections, and securing the fixture.

Wall Mounted and Soffit Mounted OREiN Flood Light

Figuer 4: Examples of wall-mounted and soffit-mounted installations for the flood light.

6. Operating Modes

The OREiN Flood Light offers three operational modes, selectable via a switch on the motion sensor unit:

  • Testmodus: The light turns on for 5 seconds when motion is detected, regardless of ambient light. Useful for testing sensor coverage during installation.
  • Dusk to Dawn (D2D) Mode: The light automatically turns on at night and off during the day. In this mode, the motion sensing function is inactive.
  • Auto Mode: The light turns on only at night when motion is detected. The duration the light stays on (1, 5, or 10 minutes) can be adjusted.
OREiN Flood Light 3 Modes for Daily Lighting

Figure 5: Visual representation of Test, Dusk to Dawn, and Auto modes in operation.

OREiN Flood Light Dusk to Dawn Mode

Figure 6: Illustration of the Dusk to Dawn mode, showing the light automatically activating when surroundings are dark and deactivating when bright.

7. Ynstellings oanpasse

The motion sensor unit includes dials for adjusting the light's duration and sensitivity:

  • Time Adjustment (Timer Minutes): Set the duration the light stays on after motion detection in Auto Mode (1, 5, or 10 minutes).
  • Sensitivity Adjustment (Sensitivity): Adjust the motion detection range (10ft, 20ft, 30ft, 40ft). Max setting provides up to 40ft detection.
Adjustable Motion Sensor Dials for OREiN Flood Light

Figure 7: Close-up of the motion sensor with dials for adjusting mode, timer minutes, and sensitivity.

Video 1: Official OREiN video demonstrating the motion sensor outdoor lights, including features like wide detection, adjustable sensing distance, heat dissipation, adjustable time/sensitivity, flexible adjustment, and easy installation.

8. Underhâld

  • Reiniging: Reinigje de fixture mei in sêft, damp doek. Brûk gjin abrasive skjinmakkers of solvents.
  • Ynspeksje: Periodically check for any damage to the wiring or housing.
  • Bulb ferfanging: The LED bulbs are integrated and not user-replaceable. The fixture has a lifespan of up to 50,000 hours.
OREiN Flood Light IP65 Waterproof

Figure 8: Illustration demonstrating the IP65 waterproof rating, showing the light functioning reliably under rain.

OREiN Flood Light Good Heat Dissipation

Figure 9: Diagram showing the heat dissipation design of the light heads, contributing to the product's longevity.

9. Probleemoplossing

ProbleemMooglike oarsaakOplossing
Ljocht docht net oan.No power; incorrect wiring; sensor settings.Check circuit breaker. Verify wiring connections. Adjust sensor mode/sensitivity.
Ljocht bliuwt kontinu oan.Sensor in D2D mode; continuous motion detected; sensitivity too high.Switch to Auto mode. Check for constant heat sources or movement in detection zone. Reduce sensitivity.
It ljocht giet oerdeis oan.Sensor in Test mode; ambient light sensor blocked.Switch to Auto or D2D mode. Ensure the ambient light sensor is not obstructed.
Motion detection range is too short/long.Gefoelichheidsynstelling ferkeard.Adjust the sensitivity dial on the motion sensor.

10. Spesifikaasjes

EigenskipDetail
Model NammeOL3600354
MerkOREiN
Helderheid4500 Lumens
Wattage30 watt
Kleur Temperatuer5000 Kelvin (deiljocht)
Voltage120 Volt
MateriaalAcrylonitril Butadien Styrene (ABS)
Wetter Resistance LevelIP65 Waterproof
Bewegingsdeteksjehoek240°
Motion Detection OfstânOant 40 fuotten
Light Head Adjustment340° Dekking
Estimated Lifespan50,000 oeren
Ynstallaasje TypeHardwired (Wall Mount, Eave Mount)
Produkt Ofmjittings7.6"L x 8"B x 6"H
Item Gewicht1.87 pyk

11. Garânsje en stipe

OREiN offers an extended warranty for this product. For specific warranty details, please refer to the product packaging or contact OREiN customer support.

Klantstipe:

  • For assistance, contact OREiN directly through Amazon or search for the brand name online.
  • If you encounter any issues, it is recommended to contact customer support before initiating a return.
OREiN Customer Service Representative

Figure 10: Image representing OREiN customer support, available for assistance.

© 2023 OREiN. Alle rjochten foarbehâlden.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.