1. Ynlieding

This manual provides essential information for the safe and efficient operation of your ProCom MN300TBA-B Ventless Natural Gas Blue Flame Space Heater. Please read all instructions carefully before installation and use. Retain this manual for future reference.

ProCom MN300TBA-B Ventless Natural Gas Blue Flame Space Heater

Figure 1: ProCom MN300TBA-B Ventless Natural Gas Blue Flame Space Heater.

2. Wichtige feiligens ynformaasje

WAARSKUWING: Ferkearde ynstallaasje, oanpassing, feroaring, tsjinst of ûnderhâld kin skea oan eigendom, ferwûning of dea feroarsaakje. Lês de ynstruksjes foar ynstallaasje, operaasje en ûnderhâld goed foardat jo dizze apparatuer ynstallearje of betsjinje.

  • This heater is hot while in operation. Do not touch the hot surfaces. Keep children, clothing, and furniture away.
  • Hâld de burner en kontrôle compartment skjin.
  • This heater shall not be installed in a bedroom or a bathroom.
  • Net bewarje of brûk benzine of oare flammable dampen en floeistoffen yn 'e buert fan dit of in oar apparaat.
  • Ensure adequate ventilation. Ventless gas heaters consume oxygen from the room.
  • A built-in Oxygen Depletion Sensor (ODS) system immediately shuts down the heater if carbon monoxide or lack of oxygen is detected.
  • For your safety, always install a carbon monoxide detector in your home.

3. Produktfunksjes

The ProCom MN300TBA-B heater offers efficient heating with several key features:

  • Technology: Produces 30,000 Maximum BTU using Natural Gas, heating up to 1400 sq. ft.
  • Betrouber: Features a thermostat control with High/Medium/Low settings for optimal heat flow.
  • Stylish: Slim and modern profile, suitable for wall mounting or floor placement with included base feet.
  • Feilich: Equipped with a push-button ignition and a built-in pilot Oxygen Depletion Sensor (ODS) for safety. ANSI Certified.
  • Handich: Operates without electricity, making it suitable for power outages.
ProCom Heater Features: 30,000 BTU, No Venting, Natural Gas, No Electricity, Piezo Ignition, Thermostat Mode

Figure 2: Key features of the ProCom Ventless Heater.

ProCom Heater includes Base Feet, Wall Bracket, Oxygen Depletion Sensor, Operates on Natural Gas Only

Figure 3: Included components and fuel type.

4. Opset en ynstallaasje

This heater can be installed as a wall-mounted unit or placed on the floor using the provided base feet. Professional installation is recommended for gas connections.

4.1 Unpacking en ynspeksje

Carefully remove the heater from its packaging. Inspect for any damage. Ensure all components, including base feet and wall mount hardware, are present.

4.2 Oerwagings foar pleatsing

  • Ensure the heater is placed on a level, stable surface if using base feet.
  • Maintain proper clearances from combustible materials as specified in the full installation instructions.
  • Do not install in a bedroom or bathroom.
  • Ensure adequate ventilation in the room where the heater is installed.

4.3 Mounting opsjes

The heater comes with hardware for both wall mounting and floor placement.

  • Wall Mount: Use the included wall bracket and fasteners to securely attach the heater to a suitable wall surface.
  • Base Feet: Attach the provided base feet to the bottom of the heater for freestanding operation.
ProCom Heater showing blue flame technology and included base feet

Figure 4: Heater with base feet, highlighting blue flame technology.

ProCom Heater dimensions: 24 inches H, 27 inches L, 8 inches D

Figuer 5: Produktôfmjittings foar ynstallaasjeplanning.

4.4 Gas Ferbining

This heater operates on Natural Gas. Connect the heater to your natural gas supply line according to local codes and manufacturer instructions. It is highly recommended to have a qualified professional perform the gas connection to ensure safety and proper function.

5. Bedriuwsinstruksjes

Follow these steps to operate your ProCom Ventless Natural Gas Heater:

5.1 Ignition

  1. Soargje derfoar dat de gasfoarsjenning ynskeakele is.
  2. Turn the thermostat control knob to the 'PILOT' setting.
  3. Push and hold the control knob in while simultaneously pressing the ignitor button repeatedly until the pilot flame lights.
  4. Continue to hold the control knob in for approximately 30-60 seconds after the pilot lights to allow the thermocouple to heat up. Release the knob slowly. If the pilot goes out, repeat the process.

5.2 Adjusting Heat (Thermostat Control)

Once the pilot is lit, turn the thermostat control knob to your desired heat setting. The heater offers High, Medium, and Low settings to maintain a comfortable room temperature.

5.3 Útsette

  1. To turn off the main burner, turn the thermostat control knob to the 'OFF' position. The pilot light will remain lit.
  2. To completely shut down the heater (including the pilot light), turn the control knob to 'OFF PILOT'.
  3. For extended periods of non-use, it is recommended to turn off the main gas supply valve to the heater.
Close-up of ProCom Heater's ignitor button and thermostat control dial

Figure 6: Ignitor and Thermostat Controls.

Video 1: Product Summary Video demonstrating general features and operation.

6. Underhâld

Regelmjittich ûnderhâld soarget foar de lange libbensdoer en feilige wurking fan jo kachel.

  • Reiniging: Keep the burner and control compartment clean. Use a vacuum cleaner to remove dust and lint from the air intake and outlet grilles.
  • Pilot Light and Burner Inspection: Periodically check the pilot light and main burner flames for proper appearance (blue, steady flame). Refer to the full manual for detailed flame characteristics.
  • Gasferbiningen: Annually inspect all gas connections for leaks using a soap solution. Never use an open flame to check for gas leaks.
  • Profesjonele tsjinst: It is recommended to have your heater inspected by a qualified service technician at least once a year.

7. Probleemoplossing

If you encounter issues with your heater, refer to the following common troubleshooting steps. For persistent problems, contact a qualified service technician.

ProbleemMooglike oarsaakOplossing
Pilot sil net ljochtNo gas supply; Air in gas line; Pilot orifice cloggedCheck gas valve; Purge air from line; Clean pilot orifice
Pilot sil net bliuwe ljochtThermocouple faulty; Pilot flame too smallReplace thermocouple; Adjust pilot flame
Main burner sil net ljochtPilot not lit; Thermostat set too low; Main burner orifice cloggedLight pilot; Adjust thermostat; Clean burner orifice
Heater produces odorNew unit burn-off; Dust/debris on burner; Inadequate ventilationAllow initial burn-off; Clean heater; Ensure proper ventilation

8. Spesifikaasjes

AttributeDetail
MerkProCom
Model NumberMN300TBA-B
Fuel TypeIerdgas
BTU útfier30,000 BTU
Heating CoverageOant 1400 sq.
Special FeatureAdjustable Temperature (Thermostat Control)
KleurWyt
Form FactorPedestal (Floor Mount)
Mounting TypeFloor Mount, Wall Mount
Produkt Ofmjittings8" D x 29" W x 28" H
Item Gewicht29.7 pyk
Burner TypeBlauwe Flame
UPC848660008383

9. Garânsje & Support

For warranty information and customer support, please refer to the documentation included with your product or visit the official ProCom website. Hâld jo oankeapbewiis foar garânsjeclaims.

© 2025 ProCom. Alle rjochten foarbehâlden.

Ask a question about this manual