Wattive ZHB600-4KW

WATTIVE ZHB600-4KW Variable Frequency Drive User Manual

Model: ZHB600-4KW | Brand: Wattive

1. Ynlieding

The Wattive ZHB600-4KW Variable Frequency Drive (VFD) is a high-performance motor speed controller designed for industrial applications. It converts single-phase 220V input power into three-phase 380V output, enabling precise speed regulation for asynchronous motors. This VFD is suitable for a wide range of equipment, including fans, pumps, conveyors, and textile machinery, offering stable performance and energy efficiency.

WATTIVE ZHB600-4KW Variable Frequency Drive front view

Ofbylding 1.1: Front view of the WATTIVE ZHB600-4KW Variable Frequency Drive, highlighting its display and control panel. This device is designed for single-phase 220V input and three-phase 380V output, providing 4KW of power.

Wide applicability of the VFD across various industries

Image 1.2: Illustration showing the wide range of applications for the VFD, including textile, mechanical engineering, automation, food processing, chemical, woodworking, and metallurgical industries, as well as various types of fans and pumps.

2. Safety Information

Please read all safety instructions carefully before installation, operation, or maintenance of the VFD. Failure to comply with these instructions may result in electric shock, fire, or serious injury.

  • Elektryske feiligens: Ensure all power is disconnected before wiring or performing any maintenance. Only qualified personnel should perform electrical connections.
  • Grounding: The VFD must be properly grounded to prevent electric shock.
  • Voltage Kompatibiliteit: Ferifiearje dat de ynfier voltage matches the VFD's specifications (single-phase 220V). The output is three-phase 380V.
  • Motorkompatibiliteit: This VFD is compatible only with asynchronous motors. Do not use with other motor types.
  • Hjoeddeiske limiten: Ensure the motor's current does not exceed the VFD's rated output current (6.5A). For heavier motor loads, select a VFD with higher power capacity.
  • Miljeu: Install the VFD in a clean, dry, and well-ventilated area, away from direct sunlight, corrosive gases, and excessive vibration.
  • Discharge tiid: After disconnecting power, wait at least 10 minutes for the internal capacitors to discharge before touching any terminals. A warning label on the device indicates this.

3. Package Ynhâld

Kontrolearje by it útpakken oft alle hjirûnder neamde items oanwêzich en net beskeadige binne:

  • 1 x Wattive ZHB600-4KW Variable Frequency Drive
  • 1 x 2-meter Extension Cable (for detachable control panel)
  • 1 x Instruction Manual (English)

As der items ûntbrekke of skansearre binne, nim dan direkt kontakt op mei jo leveransier.

4. Produktfunksjes

  • Stabiele prestaasjes: Equipped with high-end internal modules, this VFD offers enhanced load capacity, high power, torque, and precision across a wide speed regulation range, ensuring overall stability and reduced voltage fluktuaasjes.
  • Intuitive Display & Detachable Control Panel: The VFD features an intuitive display and control buttons for easy parameter adjustment and clear data display. The removable control panel includes a 2-meter extension cable for remote operation, providing convenience and flexibility.
  • Effisjinte waarmte dissipaasje: An integrated high-performance DC heat sink and intelligent fan control ensure effective heat reduction and quiet operation, contributing to the equipment's long-term stable performance.
  • Meardere beskermingen: Designed for diverse operating conditions, the VFD incorporates multiple protective functions to safeguard circuit outputs, including short-circuit protection, motor short-circuit protection, overvoltage protection, overcurrent protection, earthing fault protection, phase loss protection, overheating protection, and overload protection.
  • Durable and Compact Design: Constructed from process-grade flame-retardant ABS plastic, the VFD offers high impact resistance, strong flame retardancy, and reliability. Its compact size and removable panel make it easy to install.
Detachable control panel with 2-meter extension cable

Image 4.1: The detachable control panel connected to the main unit via a 2-meter extension cable, allowing for remote operation and flexible installation.

Internal components showing high-speed fan and ABS flame-retardant material

Ofbylding 4.2: Yntern view highlighting the high-speed cooling fan for efficient heat dissipation and the use of ABS flame-retardant material for enhanced safety and durability. The compact size of the inverter is also shown.

List of multiple protection features of the VFD

Image 4.3: A visual representation of the multiple protection features integrated into the VFD, including short-circuit, motor short-circuit, overvoltage, overcurrent, earthing fault, phase loss, overheating, and overload protection.

5. Opset en ynstallaasje

5.1 Montage

The VFD can be installed using a wall-mounted method or within a cabinet. Ensure adequate space for ventilation, especially around the cooling fan. The recommended cooling method is air cooling with fan control.

5.2 Wiring Diagram

Refer to the wiring diagram below for proper connection of the VFD. Ensure all connections are secure and correctly polarized. Important: Do not connect AC power to the output terminals (U, V, W).

380V VFD wiring diagram showing single-phase input and three-phase motor output

Image 5.1: Wiring diagram for the 380V VFD. It illustrates connecting a single-phase 220V power supply to the input terminals (L, N), a 380V three-phase motor to the output terminals (U, V, W), and the ground wire to the designated terminal.

  • Input Power (L, N): Connect the single-phase 220V power supply to the 'POWER' input terminals.
  • Motorútfier (U, V, W): Connect the three-phase 380V asynchronous motor to the 'MOTOR' output terminals.
  • Ground Wire: Connect the ground wire to the designated ground terminal for safety.
  • Control Panel: The detachable control panel can be connected directly or via the provided 2-meter extension cable for remote access.

6. Bedriuwsinstruksjes

6.1 Control Panel Overview

The VFD features an intuitive control panel for easy operation and parameter settings. Familiarize yourself with the keys and their functions:

VFD control panel with key functions table

Ofbylding 6.1: Detaillearre view of the VFD control panel and a table explaining the function of each key: PRG (Programming key), ENT/MFK (Confirm/Multifunction key), Increment key, Decrement key, RUN/STOP key, and Shift key.

KaaiNammeFunksje
PRGProgramming kaaiLevel 1 Menu Entry or Exit
ENT/MFKConfirm/Multifunction keyIn menu mode, used to navigate sequentially through menu screens, set parameters, and confirm selections; in display mode, selects function switching based on P7-01 settings.
^Ferhege kaaiIncrement data or function codes
vFerminderje kaaiDecrement data or function codes
RIN / STOPRun / Stop kaaiIn keyboard operation mode, used for running and stopping operations
>>Shift-toetsIn both stop display and run display interfaces, cyclically select parameters for display; when modifying parameters, select the bit to be altered

6.2 Basis Operaasje

  1. Power On: After ensuring all wiring is correct and secure, apply single-phase 220V power to the VFD. The display will light up.
  2. Frekwinsje ynstelle: Use the Increment (^) and Decrement (v) keys to adjust the desired output frequency (0-600Hz). The display shows the current frequency.
  3. Startmotor: Druk op de RIN / STOP key to start the motor. The VFD will ramp up to the set frequency.
  4. Motor stopje: Druk op de RIN / STOP key again to stop the motor. The VFD will ramp down and stop.
  5. Parameter oanpassing: For advanced settings, such as forward/reverse rotation (which may require an external universal rotation switch), enter the programming menu using the PRG key and adjust parameters as needed. Refer to the full instruction manual for detailed parameter settings.

7. Underhâld

Regelmjittich ûnderhâld soarget foar de lange libbensdoer en optimale prestaasjes fan jo VFD.

  • Reiniging: Keep the VFD clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
  • Fan ynspeksje: Periodically check the cooling fan for obstructions or excessive noise. Ensure proper airflow for efficient heat dissipation.
  • Terminalkontrôle: Regularly inspect all wiring terminals for tightness and corrosion. Loose connections can lead to overheating or malfunction.
  • Miljeubetingsten: Soargje derfoar dat de wurkomjouwing binnen de oantsjutte temperatuer- en fochtigensberik bliuwt.

8. Probleemoplossing

If you encounter issues with your VFD, refer to the following general troubleshooting steps. For specific error codes and advanced diagnostics, consult the comprehensive instruction manual.

  • Gjin macht: Check the input power supply, circuit breaker, and all power connections.
  • Motor rint net: Verify that the RUN/STOP key has been pressed, the frequency is set, and the motor wiring is correct. Check for any error codes on the display.
  • Overload/Overcurrent: If an overload or overcurrent error occurs, check the motor load, ensure the motor current does not exceed the VFD's rating, and inspect for any mechanical issues with the motor or driven equipment.
  • Oververhitting: Ensure the VFD's cooling fan is operating correctly and that there is adequate ventilation around the unit. Clean any dust from the heat sink.
  • Ferkearde snelheid: Verify the frequency setting and any relevant speed control parameters.

As it probleem oanhâldt nei it besykjen fan dizze stappen, nim dan kontakt op mei klanttsjinst.

9. Spesifikaasjes

Detailed technical specifications for the Wattive ZHB600-4KW Variable Frequency Drive:

Product information and dimensions of the VFD

Image 9.1: Product information panel showing key specifications such as product name, material, rated input/output voltage, rated power, output current, and output frequency, along with the physical dimensions of the VFD.

ParameterWearde
MerkWattive
Model NammeZHB600
Model NumberZHB600-4KW
Beoardiele ynfier voltageSingle-phase 220V (AC)
Rated Output VoltageThree-phase 380V (AC)
Rated Power4 kw
Output Strom6.5A
Input Frequency50 Hz
Utfier Frekwinsje Berik0 - 600 Hz
MateriaalFlame-retardant ABS Plastic
Produkt Ofmjittings (L x B x H)18.2 x 13 x 8.7 sm
Ynstallaasje MetoadeWall-mounted, Cabinet
Cooling metoadeAir cooling, with fan control
Oanrikkemandearre produktgebrûkYndustrieel
Energy Specifications MetCE
Lân fan oarsprongSina

10. Garânsje en stipe

For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase documentation or visit the official Wattive webside. Bewarje jo oankeapbewiis as bewiis fan oankeap.

© 2023 Wattive. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.