1. Wichtige Safety Ynstruksjes
Please read these instructions carefully before installation and use. Failure to follow these instructions may result in property damage, personal injury, or death.
- This appliance must be installed by a qualified electrician and plumber in accordance with all local and national regulations.
- Ensure the electrical supply matches the specifications of the appliance (230 V, 3.5 kW).
- Do not operate the appliance if it is damaged or not functioning correctly.
- Do not block the water outlet or tamper mei de druk relief klep.
- This unit is designed for pressureless operation. Only use the special mixer tap supplied with the unit.
- Hâld bern fuort fan it apparaat tidens wurking.
- Skeakelje de stroomfoarsjenning út foardat jo ûnderhâld of skjinmeitsjen útfiere.
2. Produkt Overview
The CLAGE M3/SMB is a compact, hydraulically controlled small instantaneous water heater designed for over-sink installation. It provides hot water instantly for a single tap, making it ideal for hand washing or small dishwashing tasks. The unit features an effective bare-wire heating system (IES®) and comes with a special mixer tap for wall connection.

This image displays the CLAGE M3/SMB small instantaneous water heater unit mounted above a chrome-finished mixer tap. The water heater unit is a compact, rectangular, silver-colored device designed for over-sink installation. The mixer tap features two control knobs and a curved spout.
3. Technyske spesifikaasjes
| Spesifikaasje | Wearde |
|---|---|
| Model Number | M3/SMB |
| Power Output | 3.5 kW |
| Nominale Voltage | 230 V |
| Elektryske ferbining | 1 AC/N/PE, Plug-ready |
| Ofmjittings (H x B x D) | 135 x 186 x 87 mm |
| Gewicht | Ca. 1.92 kg |
| Beskermingsklasse | IP 25 |
| Wetter Connections | 3/8 ynch |
| Operating Pressure | Pressureless |
| Mounting Type | Wall-mounted, Over-sink |
4. Ynstallearje (Setup)
Ynstallaasje moat wurde útfierd troch in kwalifisearre profesjonele.
4.1 Útpakke
- Ferwiderje alle komponinten foarsichtich út 'e ferpakking.
- Check for any visible damage. Do not install if damaged.
- Ensure all parts listed in the packing contents are present.
4.2 Montage fan de ienheid
- Select a suitable wall location directly above the sink, ensuring sufficient space for maintenance and operation.
- Use the variable metal wall bracket to mark drilling points.
- Boarje gatten en set passende muorrepluggen yn.
- Securely fasten the wall bracket to the wall.
- Mount the water heater unit onto the bracket.
4.3 Wetter Connection
- Connect the cold water supply to the designated inlet on the mixer tap (usually marked blue).
- Connect the hot water outlet from the unit to the designated inlet on the mixer tap (usually marked red).
- Ensure all connections are tight to prevent leaks. Use appropriate sealing materials.
- Open the main water supply and check for leaks.
- Before electrical connection, flush the unit by opening the tap until water flows freely and air is expelled.
4.4 Elektryske ferbining
- Soargje derfoar dat de haadstroomfoarsjenning by de stroomûnderbrekker útskeakele is.
- Connect the appliance to a dedicated 230 V, 3.5 kW electrical circuit. The unit is plug-ready.
- Verify proper grounding.
- Once connections are secure, switch on the main power supply.
5. Operaasje
5.1 Earste gebrûk
- After installation and electrical connection, ensure the unit is completely filled with water by opening the cold water tap until water flows steadily.
- Turn the hot water knob on the mixer tap. The heating element will activate, and hot water will begin to flow after a short delay.
- Adjust the water temperature by mixing hot and cold water using the mixer tap controls.
5.2 Deistich gebrûk
- To obtain hot water, turn the hot water knob on the mixer tap. The unit will heat water as it flows through.
- To obtain cold water, turn the cold water knob.
- Adjust the flow rate and temperature as desired using the tap controls.
- The unit is designed for continuous flow within its specified capacity.
6. Underhâld
Regular maintenance ensures optimal performance and longevity of your CLAGE M3/SMB water heater.
- Eksterieur skjinmeitsje: Reinigje de bûtenkant fan 'e ienheid mei in sêft, damp doek. Brûk gjin abrasive skjinmakkers of solvents.
- Avkalking: Depending on water hardness, limescale can build up in the heating system. If you notice a decrease in hot water flow or temperature, the unit may need descaling. This procedure should be performed by a qualified technician.
- Kontrolearje ferbinings: Periodically inspect water and electrical connections for any signs of leaks or wear.
- Mixer Tap Maintenance: Clean the aerator of the mixer tap regularly to remove any debris or limescale buildup that might restrict water flow.
7. Probleemoplossing
Foardat jo kontakt opnimme mei klanttsjinst, rieplachtsje asjebleaft de folgjende hantlieding foar probleemoplossing:
| Probleem | Mooglike oarsaak | Oplossing |
|---|---|---|
| Gjin waarm wetter | Gjin stroomfoarsjenning Water flow too low Ferwaarming elemint fout | Check circuit breaker and power connection Increase water flow at the tap Nim kontakt op mei kwalifisearre technikus |
| Low hot water flow | Clogged aerator Kalkaanslachopbou Net genôch wetterdruk | Clean aerator Descale unit (professional service) Check main water supply pressure |
| Water leaking from unit or connections | Losse ferbinings Beskeadige sealen Ynterne fout | Tighten connections (do not overtighten) Replace seals (professional service) Nim kontakt op mei kwalifisearre technikus |
| Wetter net waarm genôch | Wetter streamt te heech Kalkaanslachopbou | Reduce water flow at the tap Descale unit (professional service) |
If the problem persists after attempting these solutions, please contact a qualified technician or CLAGE customer support.
8. Garânsje en stipe
For warranty information, technical support, or spare parts, please refer to the official CLAGE website or contact your local CLAGE dealer. Keep your purchase receipt as proof of purchase.