LTECH KBS Switch Module Instruction Manual

LTECH KBS Switch Module Instruction Manual

LTECH-KBS-Switch-Module (6)

LTECH KBS Switch Module

LTECH-KBS-Switch-Module-PRODUCT

Systeem Diagram

LTECH-KBS-Switch-Module (2)

Produkt Yntroduksje

  • Bluetooth 5.2 SIG Mesh communication protocol, offering strong networking capabilities, reliability, and stability.
  • Equipped with dual-relay functionality, enabling control of two sets of lighting devices.
  • Supports both mechanical and push switches. Even if the light is manually turned off, remote control via the APP remains available, meeting diverse needs.
  • Supports OTA (Over-the-Air) online upgrades, ensuring timely feature updates and usage safety, keeping the product up-to-date.
  • Supports direct connection to devices via smartphone, allowing direct control through the APP. Supports gateway-free control, enabling LAN remote control, wireless panels, group control, and more. Supports integration with a smart gateway to enable remote control of home devices, making life more convenient.
  • Compact size, allowing easy installation in European, American, and national standard junction boxes, suitable for various installation scenarios.
  • Supports power-off reset functionality and mechanical key reset functionality.

Technyske spesifikaasjes

Model KBS
Wireless type Bluetooth 5.2 SIG Mesh
Switch kanaal 2CH
Operaasje voltage 100-240V~, 50/60Hz,
Max. load current of the relay 10A
Max. load parameters of the relay Resistive load: 1000W@230Vac/CH, 500W@110Vac/CH, Max.2000W Capacitive load: 400W@230Vac/CH, 200W@110Vac/CH, Max.800W
Relais surge stroom 70A@10ms
Wurktemperatuer -25°C~50°C
Produkt grutte L45 × B45.5 × H20.5 (mm)
Produkt gewicht 30g
Standerts UL 8750、EN 61347-2-13:2014+A1:2017、EN 61347-1:2015+A1:2021、EN 62493:2015/A1:2022

Produkt Images

LTECH-KBS-Switch-Module (3)

Produkt Grutte

LTECH-KBS-Switch-Module (4)

Wiring Diagram

  1. Two mechanical switches control one relay each.
  2. One mechanical switch controls two relays.LTECH-KBS-Switch-Module (5)
  3. Two push switches control one relay each.
  4. One push switch controls two relays. LTECH-KBS-Switch-Module (6)

Oanrikkemandearre applikaasjes

  1. Wireless light control
  2. After setting up the remote control association with the switch module via the APP, both the APP and the remote control can be used to control the device.LTECH-KBS-Switch-Module (7)
  3. Supports local scenes, gateway-free operation, and controllable even when offline.
  4. Work with intelligent gateway, it can realize visual control, cloud scene and automatic linkage. LTECH-KBS-Switch-Module (8)
  5. Intelligent control. Set up more app configs as you like

App Bedriuwsinstruksjes

  1. Registrearje in akkount
    Scan de QR-koade hjirûnder mei jo mobile tillefoan en folgje de prompts om de app-ynstallaasje te foltôgjen. LTECH-KBS-Switch-Module (9)
  2. Parameter ynstelling
    More settings such as editable binding interface, group control, local scenes, cloud scenes, and automation. LTECH-KBS-Switch-Module (10)
  3. Binding interface settings
    After pairing is completed, enter the binding interface for the smart remote control/smart wireless switch. Select the switch module device to associate it, and then you can control the device’s on/off function using the smart remote control/smart wireless switch. You can also unbind the device from this interface. LTECH-KBS-Switch-Module (11)
  4. Light fixture group
    The same type of lighting fixtures can be grouped together, allowing users to control power on/off and other operations for the entire group, making operations more convenient. Switch to the “Group” menu, click the “+” icon in the upper right corner, follow the prompts to modify the group name, then click “Next,” select the devices you want to include in the group, and save. LTECH-KBS-Switch-Module (12)
  5. Lokale sêne
    Switch to the 【Smart】 page, click “+” in the upper right corner to create a local scene, and after setting the execution action, you can realize the local linkage of Bluetooth devices. LTECH-KBS-Switch-Module (13)
  6. Cloud scenes and automation
    Make sure that a smart gateway, such as SP-GW-6S,has been added to the family.
    Cloud scenes: Switch to the 【Smart】 interface and click “+” to create a cloud scene. After setting the execution action, remote linkage can be achieved.
    Automation: Select “Automation” in the【Smart】page and click “+” to create automation. You can choose local/cloud execution mode,and set trigger conditions and execution actions. When the set trigger conditions are met, a series of device actions are automatically triggered to achieve remote linkage LTECH-KBS-Switch-Module (14)

Weromsette nei fabriekswearden

  • Mechanical Reset: Connect device to lighting fixture. Hold reset button for 15s until indicator light flashes red rapidly, then release. Press reset button 3 times briefly within 3s. Slow red flash means factory settings restored; rapid blue flash means setup is complete.
  • Power Cycle Reset: With power off, switch device on for 15s then off. Repeat power on/off 6 times (2s on, 5s off each). On 7th power-on, connected fixture blinks 3 times, showing factory settings restored.
  • APP Reset: Click the ” ” on the switch module to enter the main interface, then click the ” ” in the upper right corner to access the settings interface. Click “Delete Device” to complete the reset. LTECH-KBS-Switch-Module (1)

Oandacht

  • Product installation and commissioning should be done by a qualified professional. Our company products are and not lightning proof non-waterproof(special models excepted). Please avoid the sun and rain. When installed outdoors, please ensure they are mounted in a water proof enclosure or in an area equipped with lightning protection devices Good heat dissipation will prolong the working life of products. Please ensure good ventilation.
  • Kontrolearje asjebleaft as de wurkjende voltage brûkt foldocht oan de parameter easken fan produkten.
  • De diameter fan brûkte draad moat de ljochtarmaturen kinne laden dy't jo ferbine en soargje foar de stevige bedrading.
  • Foardat jo produkten oansette, soargje asjebleaft dat alle bedrading goed is yn gefal fan ferkearde ferbining dy't skea feroarsaket oan ljochtarmaturen.
  • As der in fout optreedt, besykje dan net produkten sels te reparearjen. As jo ​​​​fragen hawwe, nim dan kontakt op mei jo leveransiers.

Garânsjeakkoart

Garânsje perioaden út de datum fan levering: 5 jier.
Fergese reparaasje- of ferfangende tsjinsten foar kwaliteitsproblemen wurde levere binnen garânsjeperioaden.

Utsein fan garânsjes hjirûnder:
De folgjende betingsten binne net binnen it garânsjeberik fan fergese reparaasje- of ferfangende tsjinsten:

  • Beyond garânsje perioaden.
  • Elke keunstmjittige skea feroarsake troch hege voltage, overload, of ferkearde operaasjes. Produkten mei slimme fysike skea.
  • Skea feroarsake troch natuerrampen en oermacht.
  • Garânsjeetiketten en barcodes binne skansearre.
  • No any contract signed by our company.
  1. Repair or replacement provided is the only remedy for customers. Our company is not liable for any incidental or consequential damage unless it is within the law.
  2.  Our company has the right to amend or adjust the terms of this warranty, and release in written form shall prevail.

Dit hantlieding is ûnder foarbehâld fan feroaringen sûnder fierdere notice. Produktfunksjes binne ôfhinklik fan it guod. Nim dan gerêst kontakt mei ús offisjele distributeurs as jo fragen hawwe.

Dokuminten / Resources

PDF thumbnailKBS Switch Module
Instruction Manual · KBS Switch Module, KBS, Switch Module, Module
PDF thumbnailKBS Switch Module
Instruction Manual · KBS, KBS Switch Module, Switch Module, Module
PDF thumbnailKBS Switch Module
Owner's Manual · 2AYCY-KBS, KBS Switch Module, KBS, Switch Module, Module

Referinsjes

Stel in fraach

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Stel in fraach