The Switch Module Model KBS1 is a versatile device that supports Bluetooth 5.2 SIG Mesh communication protocol, offering strong networking capabilities, reliability, and stability. It enables app control even when manually turned off, catering to diverse needs.

Systeem Diagram

LTECH-KBS1-Switch-Module-fig (1)

Produkt Yntroduksje

  • Bluetooth 5.2 SIG Mesh communication protocol, offering strong networking capabilities, reliability, and stability.
  • Supports both mechanical and reset switches, enabling app control even when manually turned off to meet diverse needs; supports power-on or power-off scenarios for hotel-style applications.
  • Supports power-on or power-off scenarios to accommodate hotel-style usage scenarios;
  • Supports OTA (Over-the-Air) online upgrades, ensuring timely feature updates and usage safety, keeping the product up-to-date.
  • Supports direct connection of mobile phones to devices, enabling direct control of devices through the L-Home app;
  • Supports gateway-free control, enabling LAN remote control, wireless panels, group control, and more.
  • Supports integration with a smart gateway to enable remote control of home devices, making life more convenient.
  • Compact size, allowing easy installation in European, American, and national standard junction boxes, suitable for various installation scenarios.
  • Supports power-off reset functionality and mechanical key reset functionality.

Technyske spesifikaasjes

Model KBS1
Wireless type Bluetooth 5.2 SIG Mesh
Switch kanaal 1CH
Operaasje voltage 100-240V~, 50/60Hz,
Max. load parameters of the relay Resistive load: 1000W@230Vac, 500W@110Vac Capacitive load: 400W@230Vac, 200W@110Vac
Relais surge stroom 70A@10ms
Wurktemperatuer -25°C~50°C
Produkt grutte L45 × B45.5 × H20.5 (mm)
Produkt gewicht 30g
Standerts UL 8750、EN 61347-2-13:2014+A1:2017、EN 61347-1:2015+A1:2021、 EN 62493:2015/A1:2022

Produkt Images

LTECH-KBS1-Switch-Module-fig (2)

Produkt Grutte
ienheid: mmLTECH-KBS1-Switch-Module-fig (3)

Wiring Diagram

  1. Mechanical Switch Wiring DiagramLTECH-KBS1-Switch-Module-fig (4)
  2. Push Switch Wiring DiagramLTECH-KBS1-Switch-Module-fig (5)
  1. Wireless light controlLTECH-KBS1-Switch-Module-fig (6)
  2. After setting up the remote control association with the switch module via the APP, both the APP and the remote control can be used to control the device.LTECH-KBS1-Switch-Module-fig (7)
  3. Supports local scenes, gateway-free operation, and controllable even when offline.LTECH-KBS1-Switch-Module-fig (8)
  4. Work with intelligent gateway, it can realize visual control, cloud scene and automatic linkage.LTECH-KBS1-Switch-Module-fig (9)

App Bedriuwsinstruksjes

  1. Registrearje in akkount
    Scan de QR-koade hjirûnder mei jo mobile tillefoan en folgje de prompts om de app-ynstallaasje te foltôgjen.LTECH-KBS1-Switch-Module-fig (10)
  2. Pairing operaasje
    After creating a new home in the APP, click the “+” in the upper right corner on the【Room】interface to add devices. Select “Smart Module” from the device list and follow the on-screen instructions to complete the addition.LTECH-KBS1-Switch-Module-fig (11)
  3. Power On/Off Scene Settings
    On the settings page, you can configure the scenes to be executed when the device powers on or off, along with the execution times for these scenes.LTECH-KBS1-Switch-Module-fig (12)
  4. Binding Interface Settings
    After pairing is complete, enter the Smart Remote/Smart Wireless Switch binding interface. Select the switch module device to associate it. You can then control the device’s power state via the Smart Remote/Smart Wireless Switch. You may also unbind the device from this interface.LTECH-KBS1-Switch-Module-fig (13)
  5. Groep kontrôle
    Supports grouping identical switch modules or single switches from dual-channel relays (KBS) into clusters. Users can conveniently control power on/off operations for the entire group. To add a device, navigate to the device list, select “Group – Switch Module Group,” modify the group name as prompted, click “Next,” check the devices to include in the group, then save.LTECH-KBS1-Switch-Module-fig (14)
  6. Lokale sêne
    Switch to the 【Smart】 page, click “+” in the upper right corner to create a local scene, and after setting the execution action, you can realize the local linkage of Bluetooth devices.LTECH-KBS1-Switch-Module-fig (15)
  7. Cloud scenes and automation
    Make sure that a smart gateway, such as SP-GW-6S,has been added to the family. Cloud scenes: Switch to the 【Smart】 interface and click “+” to create a cloud scene. After setting the execution action, remote linkage can be achieved. Automation: Select “Automation” in the【Smart】page and click “+” to create automation. You can choose local/cloud execution mode,and set trigger conditions and execution actions. When the set trigger conditions are met, a series of device actions are automatically triggered to achieve remote linkageLTECH-KBS1-Switch-Module-fig (16)
  8. Weromsette nei fabryk standerts
    Mechanical Reset: Connect device to lighting fixture. Hold reset button for 15s until indicator light flashes red rapidly, then release. Press reset button 3 times briefly within 3s. Slow red flash means factory settings restored; rapid blue flash means setup is complete. Power Cycle Reset: With the power disconnected, use the switch to power on the device for 15 seconds, then power off for 2 seconds. Repeat this power cycle six times (each cycle: 2 seconds on, 5 seconds off). After the seventh power-on cycle, the load lamp will flash three times, indicating a successful reset to factory settings. APP Reset: Click the “LTECH-KBS1-Switch-Module-fig 18 ” on the switch module to enter the main interface, then click the ” ” in the upper right corner to access the settings interface. Click “Delete Device” to complete the reset.LTECH-KBS1-Switch-Module-fig (17)

Oandacht

  • Produkt ynstallaasje en commissioning moatte wurde dien troch in kwalifisearre profesjonele.
  • Our company products are and not lightningproof non-waterproof(special models excepted). Please avoid the sun and rain. When installed outdoors, please ensure they are mounted in a water proof enclosure or in an area equipped with lightning protection devices
  • Goede waarmtedissipaasje sil it wurklibben fan produkten ferlingje. Soargje asjebleaft foar goede fentilaasje.
  • Kontrolearje asjebleaft as de wurkjende voltage brûkt foldocht oan de parameter easken fan produkten.
  • De diameter fan brûkte draad moat de ljochtarmaturen kinne laden dy't jo ferbine en soargje foar de stevige bedrading.
  • Foardat jo produkten oansette, soargje asjebleaft dat alle bedrading goed is yn gefal fan ferkearde ferbining dy't skea feroarsaket oan ljochtarmaturen.
  • As der in fout optreedt, besykje dan net produkten sels te reparearjen. As jo ​​​​fragen hawwe, nim dan kontakt op mei jo leveransiers.

Garânsjeakkoart

  • Garânsje perioaden út de datum fan levering: 5 jier.
  • Fergese reparaasje- of ferfangende tsjinsten foar kwaliteitsproblemen wurde levere binnen garânsjeperioaden.

Utsein fan garânsjes hjirûnder:
Following conditions are not wit in the guarantee range of free repairing or replacement servi

  • Beyond garânsje perioaden.
  • Elke keunstmjittige skea feroarsake troch hege voltage, overload, of ferkearde operaasjes.
  • Products with severe physical damage. Damage caused by natural disasters and force majeure.
  • Warranty labels and barcodes have been damaged. No any contract signed by our company.
  1. Repair or replacement provided is the only remedy for customers. Our company is not liable for any incidental or consequential damage unless it is within the law.
  2. Our company has the right to amend or adjust the terms of this warranty, and release in written form shall prevail.
    * Dizze hantlieding is ûnder foarbehâld fan feroarings sûnder fierdere notice. Produktfunksjes binne ôfhinklik fan it guod. Nim dan gerêst kontakt op mei ús offisjele distributeurs as jo fragen hawwe.

FAQ

Q: Can the Switch Module be used with both mechanical and reset switches?

A: Yes, the Switch Module supports both mechanical and reset switches for versatile control options.

F: Wat is de operearjende voltage range of the Switch Module?

A: Operaasje voltage range is 100-240V~, 50/60Hz, making it suitable for different power systems.

What should I do if the device cannot be found during the search?

Please check the following options: Ensure the device is powered on and functioning properly. Ensure the phone and the device are as close as possible, preferably within 15 meters. Ensure the device has not been added before. If it has, please manually restore it to factory settings.

Dokuminten / Resources

PDF thumbnailKBS1 Switch Module
User Manual · KBS1, KBS1 Switch Module, Switch Module, Module
PDF thumbnailKBS1 Switch Module
Instructions · KBS1 Switch Module, KBS1, Switch Module, Module

Referinsjes

Stel in fraach

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Stel in fraach

Ask a question about setup, compatibility, troubleshooting, or anything missing from this manual.